Alvarion BreezeACCESS II CX Guía de usuario Pagina 32

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 90
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 31
BreezeNET DS.11 Series User’s Guide
2-16
Name Description Functionality
ETH
Ethernet activity/
connectivity indication
OFF –Ethernet connectivity is OK.
No traffic activity detected on the port.
Blinking Green –Ethernet connectivity is OK, with traffic on
the port.
Red – No Ethernet connectivity. When this state occurs, check
the Ethernet cable and indoor-to-outdoor cable connections.
RSSI/Load
BAR
RB-DS.11: Received Signal Strength Indication
BU-DS.11: Number of associated RB-DS.11 units
Table 2-3: Outdoor Unit LEDs
What to do if the Self Test Fails
Upon failure of the self-test, the WLAN, DC Power and ETH LEDs, as well as the
leftmost 2 LEDs of the RSSI bar are blinking synchronously. The statuses of the
other 8 LEDs of the bar indicate the specific problem type.
If the Self-Test fails, try the following:
Reset unit (Disconnect/reconnect the power).
Check the indoor-to-outdoor cable.
Reset to factory defaults (see page 3-29).
If all fails, contact technical support and provide details regarding the status of the
RSSI LEDs.