Appendix E
E-13
BreezeACCESS Version 4.5 System Manual
Service Parameters
Parameter Unit Range Default
Run-
Time
Updated
User Filtering
Option
SU Disable,
IP Only,
User Defined
Addresses Only,
PPPoE Protocol Only
Disable Yes
Set User Filter
Address
SU IP address (8 entries) 0.0.0.0 (all 8
entries)
Yes
Set User Filter
Mask
SU IP address (8 entries) 255.255.255.255
(all 8 entries)
Yes
Set User Filter
Range
SU 0 - 255 0 (all 8 entries) Yes
MIR/CIR Option AU, SU Disable, Enable Disable No
MIR: AU to SU SU 32 – 2200Kbps 128Kbps No
MIR: SU to AU SU 32 – 2200Kbps 128Kbps No
CIR: AU to SU SU 0 – 2200Kbps 64Kbps No
CIR: SU to AU SU 0 – 2200Kbps 64Kbps No
Maximum Burst
Duration
AU, SU 0 – 2000 milliseconds 5 milliseconds No
Maximum Delay SU 300 – 10,000
milliseconds
5,000
milliseconds
No
Graceful
Degradation
Limit
AU 0 – 70 (%) 70 (%) No
MIR Only Option AU Disable, Enable Disable Yes