Accessory Installation
BreezeNET PRO.11 Series 6-5 User’s Guide
Similarly, the splitter is used to combine two receiving antennas to one antenna
connector.
Before installing the RFS 122, configure the BreezeNET PRO.11 unit via the
Monitor to transmit through Antenna 2 only using the Transmit Diversity parameter
(see Section 3.4.3), and connect the RFS 122 to antenna connector 2.
For technical specifications, refer to Section 9.2.
6.3.1 Installing the RFS 122
The following diagram illustrates RFS-122 installation.
Figure 6-3. RFS-122 Connection Diagram
6.4 AL 1 Lightning Arrestor
The AL 1 Lightning Arrestor is used to protect transmitters and receivers from
transients originating from lightning or EMP.
The AL 1 is gas tube-based and is not radioactive. The gas discharge tube can
sustain several transients if the time period between transients is sufficient to allow
the tube to cool down.